CBMPR - XYLENE, 02-2307

  • MSDS: CBMPR
  • Manufacturer: GOLD SHIELD DISTRIBUTORS
  • Product Name: XYLENE, 02-2307
  • National Stock Number: 6810-00N070802
Product Identification

Product ID:XYLENE, 02-2307
MSDS Date:03/28/1991
FSC:6810
NIIN:00N070802
MSDS Number: CBMPR

Responsible Party
GOLD SHIELD DISTRIBUTORS
3111 DEPOT RD
HAYWARD, CA 94545
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 510-782-2040

Cage: JO335

Contractor
GOLD SHIELD DISTRIBUTORS
HAYWARD, CA 94545 US

Telephone: 510-782-2040

Cage: JO335

Ingredients

XYLENE (SARA 313) (CERCLA)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 75-90%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYL BENZENE (SARA 313)

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: 10-25%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/125STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPERLY COOLED, IT MAY EXPLODE IN THE HEAT OF A

RTECS: 9999999ZZ


VOMIT & CAUSE LUNG INFLAMM & DMG. CHRONIC

RTECS: 9999999ZZ


RELEVANCE OF THESE FINDINGS TO HUMANS IS UNCERTAIN.

RTECS: 9999999ZZ


W/PERM BRAIN & NERV SYS DMG (SOMETINES REFERRED TO

RTECS: 9999999ZZ


DELIBERATELY CONCENTRATING AND INHALING THIS PRODUCT

RTECS: 9999999ZZ


IF SYMPS PERSIST, SEEK IMMED MED ATTN. IF

RTECS: 9999999ZZ


DEVELOPS OXYGEN SHOULD BE ADMIN BY QUALIFIED PERS.

RTECS: 9999999ZZ


SWALLOWED, SEEK EMER MED ATTN. IF DROWSY/UNCON PLACE

RTECS: 9999999ZZ


MOUTH. BECAUSE OF POTENTIAL TOX, IF CONSCIOUS &

RTECS: 9999999ZZ


(> 5 OZ IN ADULT) PREF W/SYRUP OF IPECAC UNDER

RTECS: 9999999ZZ


MSHA APPRVD RESP PROT AS CNDTNS WARRANT. PVNT

RTECS: 9999999ZZ


UNAUTHD TREATMENT DRAINAGE SYS & NATURAL WATERWAYS.

RTECS: 9999999ZZ


SPILLED MATL MAY BE ABSORBED INTO APPROP ABSORB

RTECS: 9999999ZZ


AGENCIES. IMMED CLEANUP OF ANY SPILL IS REC. IF

RTECS: 9999999ZZ


ENVIRONMENT, IMMEDIATELY NOTIFY THE NATIONAL

RTECS: 9999999ZZ


REC % MAY BE REQ (SEE APPROP FIRE CODES).

RTECS: 9999999ZZ


OSHA STDS & APPROP FIRE CODES. "EMPTY" CONTRS

RTECS: 9999999ZZ


PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,

RTECS: 9999999ZZ


SOURCES. THEY MAY EXPLODE & CAUSE INJURY/DEATH.

RTECS: 9999999ZZ


BUNGED & PROMPTLY SHIPPED TO SUPPLIER/DRUM

RTECS: 9999999ZZ


SAFE MANNER & I/A/W GOVT REGS. BEFORE WORKING ON/IN

RTECS: 9999999ZZ


OSHA REGS, ANSI Z49.1 & OTHER GOVT/INDUS REFERENCES

RTECS: 9999999ZZ


SYS MAY BE REQUIRED. WHERE EXPLOSIVE MIXTURES MAY BE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: IRRIT. DIRECT CONT
W/LIQ/EXPOS TO VAPS/MISTS MAY CAUSE STINGING, TEARING, REDNESS &
SWELL. SKIN: MAY CAUSE MILD IRRIT. PRLNG/RPTD CONT MAY CAUSE
REDNESS, BURNING, DRYING & CRACKING OF SKIN . INHAL: WHILE MATL HAS
LOW DEGREE OF TOX, BRTHG HIGH CONCS OF VAPS/MISTS MAY CAUSE IRRIT
OF NOSE & (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: THROAT & SIGNS OF NERV SYS DEPRESS
(HDCH, DROW, DIZZ, LOSS OF COORD, FATG). INGEST: WHILE MATL HAS LOW
DEGREE OF TOX, INGEST OF EXCESS QTYS MAY CAUSE IRRIT OF DIGEST
TRACT & SIGNS OF NERV SY S DEPRESS (HDCH, DROW, DIZZ, LOSS OF
COORD, FATG). ASPIR HAZ: THIS MATL CAN ENTER LUNGS DURING
SWALLOWING/ (ING 4)
Medical Cond Aggravated by Exposure:PERS W/PREEXISTING SKIN DISORDERS
MAY BE MORE SUSCEPTIBLE TO THE EFTS OF THIS MATL. RESP SYMPS ASSOC
W/PREEXISTING LUNG DISORDERS (E.G., ASTHMA-LIKE CNDTNS) MAY BE
AGGRAVATED BY EXPOS OF THIS MATL.

First Aid

First Aid:EYES:MOVE TO FRESH AIR. IF IRRIT/REDNESS DEVELOPS, FLUSH EYES
W/CLEAN WATER FOR AT LEAST 15 MIN & SEEK MED ATTN. FOR DIRECT CONT,
HOLD EYELIDS APART & FLUSH AFFECTED EYES W/CLEAN WATER FOR AT LEAST
15 MIN. SEEK MED ATTN. SKIN:REMOVE CONTAMSHOES & CLTHG & CLEANSE
AFFECTED AREAS THORO BY WASHING W/MILD SOAP & H*2O. IF
IRRIT/REDNESS DEVELOPS & PERSISTS, SEEK MED ATTN. INHAL:MOVE TO
FRESH AIR.(ING 8)

Fire Fighting

Flash Point:81.0F,27.2C
Lower Limits:1.0%
Upper Limits:7.0%
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, HALON, FOAM OR WATER
SPRAY IS RECOMMENDED. WATER MAY BE INEFFECTIVE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. STOP SPILL/RELEASE IF IT CAN BE DONE W/OUT RISK. MOVE UNDAMAGED
CONTRS FROM FIRE AREA IF IT CAN (SUP DAT)
Unusual Fire/Explosion Hazard:MAY BE IGNITED BY HEAT, SPARKS,
FLAME/OTHER SOURCES OF IGNIT (E.G, STATIC ELEC, PILOT LIGHTS,
MECH/ELEC EQUIP). VAPS MAY IGNITE, FLASHBACK/EXPLODE. (SUP DAT)

Accidental Release

Spill Release Procedures:FLAM. KEEP ALL SOURCES OF IGNIT & HOT METAL
SURF AWAY FROM SPILL/RELEASE. STAY UPWIND & AWAY FROM
SPILL/RELEASE. ISOLATE HAZ AREA & LIM ENTRY TO EMER CREW. STOP
SPILL/RELEASE IF IT CAN BE DONE W/OUT R ISK. WEAR APPROP PROT EQUIP
INCL NIOSH/(ING 13)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTRS TIGHTLY CLSD. USE & STORE
THIS MATL IN COOL, DRY, WELL-VENT AREAS AWAY FROM HEAT, DIRECT
SUNLIGHT, HOT METAL SURF & ALL SOURCES OF IGNIT.
Other Precautions:POST AREA "NO SMKNG/OPEN FLAME". BOND & GROUND ALL
EQUIP WHEN TRANSFERRING FROM ONE VESSEL TO ANOTHER. STORE ONLY IN
APPRVD CONTRS. KEEP AWAY FROM INCOMPATIBLE MATLS. PROT CONTRS
AGAINST PHYSICAL DMG. USE OF EXPLO-PROOF EQUIP IS (ING 18)

Exposure Controls

Respiratory Protection:THE USE OF RESPIRATORY PROTECTION IS ADVISED
WHEN CONCENTRATIONS EXCEED THE ESTABLISHED EXPOSURE LIMITS.
DEPENDING ON THE ARIBORNE CONCENTRATION, USE NIOSH/MSHA APPRVD
RESP/GAS MASK W/APPROP CARTRIDGE S & CANISTERS/SUPPLIED AIR
EQUIPMENT.
Ventilation:IF CURRENT VENT PRACT ARE NOT ADEQ TO MAINTAIN AIRBORNE
CONC BELOW ESTABLISED EXPOS LIM, ADDNL VENT/EXHAUST (ING 25)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:IMPERVIOUS CLOTHING SHOULD BE WORN AS
NEEDED. EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. DO NOT WEAR
CONTAMINATED CLOTHING OR SHOES. USE GOOD PERSONAL HYGIENE PRACTICE.
Supplemental Safety and Health
FIRE FIGHT PROC: BE DONE W/OUT RISK. WATER SPRAY MAY BE USEFUL IN
MINIMIZING/DISPERSING VAPS & COOLING EQUIP EXPOSED TO HEAT & FLAME.
AVOID SPREADING BURNING LIQ W/WATER USED FOR COOLING PURPOSES. EXP
LO HAZ: VAP/AIR EXPLO HAZ INDOORS/OUTDOORS/IN SEWERS. VAPS HVR/AIR
& MAY ACCUM IN LOW AREAS. IF CONTR NOT (ING 3)

Chemical Properties

Boiling Pt:B.P. Text:>282F,>139C
Vapor Pres:6.6
Vapor Density:3.7
Spec Gravity:0.870
Evaporation Rate & Reference:0.80 (N-BU AC=1)
Solubility in Water:<5
Appearance and Odor:CLEAR, LITTLE IF ANY COLOR, LIQUID, WITH
CHARACTERISTIC ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
THIS PRODUCT IS INCOMPATIBLE WITH STRONG ACIDS OR BASES, OXIDIZING
AGENTS AND SELECTED AMINES.
Stability Condition to Avoid:AVOID ALL POSSIBLE SOURCES OF IGNITION.
Hazardous Decomposition Products:COMBUSTION MAY YIELD CARBON MONOXIDE
AND/OR CARBON DIOXIDE. DO NOT BREATHE SMOKE/FUMES. WEAR APPROP
PROTECTIVE EQUIP.

Disposal

Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE WITH LOCAL,
COUNTY, STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.